Stairs


Inputs:

RISE:  The floor-to-floor rise of the staircase. 

MAX RISER HGHT:  The maximum allowable rise height.

TREAD WIDTH:  The desired tread width of each stair.


Outputs:

N:  Number of Stairs

TRUE RH:  True riser height of the stair

# TREADS:  Number of treads

RUN:  Total theoretical run from the first stair to the top.

INCLINE:  Incline of the stair in degrees

STRINGER:  Length of the stringer


All amounts are assumed to be in inches and all amounts are precise (no rounding to the nearest 1/8th inch or 1/16 inch, etc).


Sharp EL-5500III/PC-1403 Program:  Stairs

RUN 300 (or whatever line you designate)


300 PRINT "STAIRS"

303 DEGREE

306 INPUT "RISE (IN)? "; R

309 INPUT "MAX RISER HGHT? "; H

312 INPUT "TREADWIDTH? "; W

315 N = INT (R/H) + 1

318 PRINT "N = "; N

321 T = R/N

324 PRINT "TRUE RH = "; T; " IN"

327 E = N-1

330 PRINT "# TREADS = "; E

333 U = E*W

336 PRINT "RUN = "; U; " IN"

339 A = ATN (T/W)

342 PRINT "INCLINE = "; A

345 S = (E*W)/(COS A)

348 PRINT "STRINGER = "; S; " IN"

351 END


Example


Inputs:

RISE:  150 in   (12 ft 6 in)

MAX RISER HGHT: 7.5 in 

TREAD WIDTH:  12 in


Results:

N = 21

TRUE RH = 7.142857143 IN

# TREADS = 20

RUN = 240 IN

INCLINE = 30.76271954

STRINGER = 279.2994151 IN


Air Density and Viscosity


Inputs:

AIR (F):  Temperature of the air in degrees Fahrenheit (°F)

PRESSURE:  Air pressure in pounds per square inch (psia)


Outputs:

DENSITY:  Air density  (lbm/ft^3)

VISCOSITY:  Estimate of air viscosity (ft^2/sec)


The dynamic viscosity (μ) for air is estimated by the equation to three significant digits:


μ ≈ 5.550736842 * 10^-10 * F + 3.04406316 * 10^-7 


Table of viscosity values:  https://www.engineeringtoolbox.com/air-absolute-kinematic-viscosity-d_601.html


Sharp EL-5500III/PC-1403 Program:  Air Density and Viscosity

RUN 400 (or whatever line you designate)


400 PRINT "AIR DENSITY/VISC (US)"

403 INPUT "AIR (F)? "; F

406 INPUT "PRESSURE (PSIA)? ";R

409 D = (144*R) / (53.3533 * (F+459.67))

412 REM MU - 3 DEC APPROX

415 M = 5.550736842E-10*F + 3.404406316E-7

418 REM NEED 9 PLACES SINCE MU IS TO -6TH POWER

421 M = INT (M*TEN 9) / TEN 9

424 V = M*32.1740464/D

427 PRINT "DENSITY = ": PRINT D; " LBM/FT^3"

430 PRINT "VISCOSITY = ": RINT V; "FT^2/SEC"

433 END


Example


Inputs:

AIR (F):  78 °F

PRESSURE:  82 psia


Outputs:

DENSITY:  4.116226392E-01 LBM/FT^3

VISCOSITY:  2.993678821E-05 FT^2/SEC


Sources


"Air - Dynamic and Kinematic Viscosity".  The Engineering Toolbox   

https://www.engineeringtoolbox.com/air-absolute-kinematic-viscosity-d_601.html

Retrieved July 8, 2021


Lindeburg, Michael R. PE Practice Problems for the Civil Engineering PE Exam: A Companion to the Civil Engineering Reference Manual  Thirteenth Edition Professional Publications, Inc: Belmont, CA  2012


Eddie


All original content copyright, © 2011-2021.  Edward Shore.   Unauthorized use and/or unauthorized distribution for commercial purposes without express and written permission from the author is strictly prohibited.  This blog entry may be distributed for noncommercial purposes, provided that full credit is given to the author. 